Device and connection diagram of the DRV 250 lamp


Emission spectrum [edit | edit code]

Mercury vapor emits the following spectral lines used in gas-discharge lamps [1] [2] [3]:

Wavelength, nmNameColor
184.9499Hard ultraviolet (type C)
253.6517Hard ultraviolet (type C)
365.0153line "I"Soft UV (Type A)
404.6563line "H"Violet
435.8328line "G"Blue
546.0735Green
578.2Yellow-orange

The most intense lines are 184.9499, 253.6517, 435.8328 nm. The intensity of the remaining lines depends on the discharge mode (parameters).

Advantages and disadvantages

Mercury gas-discharge lamps are an electric light source, one of the types of gas-discharge models. Their work is based on the passage of an electrical discharge through a gaseous medium.


DRL and DRV lamps are gas discharge lamps

Important! To designate light sources of this type, the term “discharge lamp” or RL is used.

Mercury lamps are divided into:

  1. DRV (interpretation - arc mercury-tungsten);
  2. DRL (or arc mercury phosphor).

The advantages of direct switching lamps DRV include:

  • Ease of connection, use and replacement: they can operate on 220 V AC power and do not require ballasts;
  • When warmed up, the resistance increases and stabilizes the network voltage - even at low voltage the light will be stable;
  • They can operate from different power sources;


Lamps provide high-quality light

  • The light sources are both tungsten filament and fluorescent radiation, that is, cold and warm white colors are mixed. This allows you to get more even light;
  • Low price.

The disadvantages are:

  • Low luminous efficiency. For example, the efficiency of Philips lamps does not exceed 30 lm/W, although other types of light bulbs from the same company have an output of up to 50 lm/W;
  • A small selection of models: in stores there are only 5 models of different power;
  • Short service life - no more than 3-4000 hours, and more often less. Replacement is quite expensive, this increases the final cost of the lamps.

Scope of application, advantages and disadvantages

DRL lighting devices are used to illuminate streets (in RKU, housing and communal services lamps, etc.) and large warehouses and production facilities, which is why they are also called industrial lamps. In addition, this type of light source is installed in a spotlight. The undoubted advantages of these devices include the following:

  • high level of luminous flux;
  • long service life (at least 12 thousand hours);
  • Possibility of operation in cold weather;
  • low price for ballasts for DRL type lamps.

Main disadvantages:

  • due to the presence of mercury and phosphor, a special disposal technology is required (as required by the relevant GOST);
  • low level color rendering (about 45%);
  • dependence on the stability of the power source, namely, when the device is turned off, the lamp will not light, and the one that is on will go out if the voltage “drops” by 15-20%;
  • at negative temperatures below -20° C, the lighting source may not ignite; in addition, under such operating conditions, its service life is significantly reduced;
  • restarting is possible only after 10-15 minutes;
  • after a certain period of operation (usually about 2000 hours), the level of luminous flux decreases significantly.

Technology development

Technology has also improved. Metal halide lamps are now available. They have added iodine and other metal compounds to improve visible emission and color.

A new variety was created - DRV. This is a hybrid of a classic incandescent lamp and DRL. They have a tungsten filament added to them. It plays the role of a limiting resistor and a radiation source at the same time. The resistor is usually carbon. Here it is made of refractory tungsten. This design solution made it possible to abandon the use of a throttle. This lamp is connected like a regular incandescent lamp - it does not require additional ballasts.

Technical characteristics of DRV and DRL lamps

There are models of various powers on the market: 160 W, 250, 500, and occasionally you can find 700 and 1000 W.


Light bulbs available in different wattages

Below is a technical description for DRV 250 lamps (they are used for artificial lighting in greenhouses):

  • Lamp length is 22.5 cm, diameter - 9.1 cm;
  • Service life - 3000 hours (on average);
  • Luminous flux - 4700 lm;
  • Light output level - 18.8 lm/W;
  • The voltage is 220 W;
  • Nominal power level - 250 W;
  • An E40 type base is inserted.

Other models will have different characteristics.

Explanation of markings

In the name of the DRV lamp, the decoding of the symbols is as follows: “arc mercury-tungsten.” According to the principle of operation, it is similar to sodium and mercury light sources, but unlike them, it has a tungsten spiral, which allows you to turn on the device without an external ballast that regulates the starting voltage.

All fluorescent type spotlights operate on alternating current from a 220 V network. Chokeless devices with an e40 base have increased luminous efficiency compared to conventional incandescent lamps and have a long service life. When they fail, they require special conditions for disposal.

Decoding the alphabetic and digital markings allows you to select a device with optimal power in accordance with the user’s requirements. The lamps are recommended for use in lighting systems for public areas. Depending on the characteristics of the device, a direct stream of light will help illuminate a parking lot, park area, greenhouse, street, construction site, room for animals and poultry, and utility yard.

Economic advantages of mercury lamps

Cost-effectiveness of use is one of the reasons for the great commercial success of tungsten devices, not only in Russia and the CIS countries, but also in developed Western countries. The fact is that strong and powerful incandescent lamps left behind huge umbrella lamps , which, especially in large industries, are extremely expensive to replace in all respects. The costs will be as follows:

  • purchasing new lighting fixtures;
  • installation of fastening systems;
  • installation of lighting lines.

All these expense items can be reduced by installing tungsten light sources in old lamps. These hybrid type light sources are more efficient. It is worth noting that in most cases, purchases of high-pressure mercury lamps are made specifically for DRV devices.

But there are a number of nuances. For example, their light parameters are significantly inferior to even the most inefficient DRL lamps. Why is this happening? Let's find out what the operating principle of DRV lamps is.

Features of the DRV 250 lamp

The mercury-type energy-saving lamp is produced by the largest world-famous companies specializing in the supply of lighting fixtures and equipment components. Products are manufactured from modern materials using innovative technologies.

The DRV 250 light bulb consists of a flask with a high-pressure argon medium, a tungsten spiral and a mercury discharge torch. It does not require a starting control device. The product can be installed in ordinary sockets, just like the usual incandescent light bulbs.

There is an opinion that in everyday life and at work it is better to use a hybrid light source with increased emission potential. In practice, it turns out that the performance characteristics of e40 are 50% lower compared to inductive choke DRL devices. The reduction in pulse efficiency occurs due to the limitation of the voltage flowing through the burner head. Its power and resistance are controlled by a starting device.

When the light bulb is activated, a cathode drop in the operating mode to 20 V occurs in the choke light source. After the main element of the e40 gas-discharge lamp lights up, its voltage rises, and the voltage readings on the tungsten coil decrease exponentially. The technical characteristics and design of the working elements, compared to an incandescent lamp, which can be distinguished by the design of the working elements and appearance, provide a brighter glow. The spiral has 30% less electrical energy.

Principle of operation

The operating principle of gas-discharge lamps is a little more complicated than that of incandescent light bulbs.

  1. When current is applied, voltage is transmitted to the current-carrying parts of the base;
  2. Then the energy passes through the circuit to the electrodes located in the burner, and a glow discharge appears between them. Ions and free electrons begin to accumulate on the surface;
  3. As ions and electrons accumulate, the internal space of the burner begins to heat up, and the mercury evaporates. The discharge occurs from a glowing state to an arc state, which creates blue or violet radiation;
  4. This glow causes the phosphor to glow, which creates a reddish light. When all colors are mixed, the result is white.


You can examine the inside of the lamp only by breaking the glass bulb.

The more mercury vapor evaporates, the more the brightness of the discharge increases. On average, it takes 4-5 minutes for the DRL to light up, while the DRL lights up almost immediately.

Important! The higher the air temperature, the less time it will take.

Technical aspects

The most important indicators of a mercury light source with an e40 base are the design of the internal part of the device, the shape of the bulb, and the dimensions of the threaded base. The economic effect of the device may differ in operating conditions. The gas-discharge soffit from the Lisma brand for street lighting, which does not create a flickering effect in the event of voltage surges in the electrical network, does not require a special device for igniting the arc. At a power of 500 W, a luminous flux of 4 - 5 thousand lm is created.

  • Name - DRV lamp;
  • Type - mercury;
  • Power - 500 V;
  • Shape - ellipse;
  • Manufacturer - ;
  • Purpose - street;
  • The flask coating is matte;
  • Base - e40.

When marking energy-saving appliances, digital and letter values ​​are used to indicate the power and type of product. It is not difficult to decipher these meanings. Examples:

  • DRL 250 - arc mercury phosphor lamp with a power of 250 V;
  • DRV 160 is a mercury-tungsten arc lamp with a power of 160 V.

The source of an even luminous flux DRV 500, the characteristics of which are determined by the parameters of the base, can have a mixed type design. The starter circuit may contain a choke. The ballast serves to reduce the voltage on the electrodes by increasing the voltage in the active luminescent device. The device is made in the form of a coil with a wire wound around a ferromagnetic core. To reduce reactive energy in the E40 lamp circuit, it is enough to disconnect the compensating capacitor.

The technical characteristics of the device are adapted for open spaces. The DRV 500 lamp demonstrates excellent results at a voltage of 220 V with a current oscillation frequency of 50 Hz. The devices are designed for continuous operation for 7.5 thousand hours.

Disposal of mercury lamps

Spent and defective mercury-type lamps belong to the first hazard class waste. They must be disposed of using special equipment. During the processing process, one of four methods can be used:

  • amalgamation;
  • heat treatment;
  • firing at high temperature;
  • chemical or metallurgical method.

All disposal methods are aimed at separating and sedimenting mercury vapor, its sublimation, followed by burning of organic components. The final products of processing DRV and DRL lamps without chokes are mercuric chloride and sorbent.

  • Author: admin
  • Print

Rate this article:

  1. 5
  2. 4
  3. 3
  4. 2
  5. 1

(0 votes, average: 0 out of 5) Share with your friends!

Types of lamps

The DRL marking means arc mercury phosphor, the marking DRV means arc mercury tungsten. At first glance, it is difficult to distinguish between DVR and DRL lamps. The differences lie in their technical characteristics. The design of both light sources includes:

  • Base. An element that receives electrical energy from the network due to the connection of the contacts of the socket and the lamp.
  • Quartz flask. Filled with argon with the addition of a drop of mercury, it has two main and two auxiliary electrodes. Acts as a burner
  • Glass flask. Acts as a container in which the quartz flask and base are placed. The inner surface of the flask is coated with a phosphor and filled with nitrogen.

Inside a tungsten lamp, along with a quartz bulb, there is a tungsten spiral. This spiral serves as a current-limiting element.

The high demand for mercury arc lamps is explained by the cost-effectiveness of their use. They are now used in various lighting devices instead of outdated incandescent lamps. Thanks to this, it is possible to avoid high costs associated with:

  • with the purchase of modern lighting fixtures;
  • with installation of fastening systems;
  • with wiring of lighting lines.

In addition, mercury devices show significantly higher operating efficiency than other light sources. However, when comparing the performance of a phosphor lamp and a tungsten lamp, some differences are observed.

Marking

In domestic practice, the number following the DRL means power consumption in W. Next comes the red ratio: the ratio of the red flux (from 600 to 780 nm) to the total - expressed as a percentage. The development number is separated by a hyphen. The red ratio characterizes color rendering; values ​​above ten are considered good.

According to the international standard IEC 1231, the ILCOS system is used. These are competitors of the German LBS marking and the pan-European ZVEI. There is complete chaos in the market. According to ILCOS:

  1. QE stands for ellipsoidal bulb shape.
  2. QR denotes a bulb with an internal reflective layer, mushroom-shaped.
  3. QG stands for spherical flask.
  4. QB stands for products with built-in ballast.
  5. QBR stands for products with built-in ballast and reflective layer.

Philips has its own view of things, but General Electric doesn’t want to hear about either. Actually, it is better to rely on reference books or read the information on the packaging. Remember that the base comes in standard sizes and in other sizes. The share of DRL lamp production is continuously decreasing, so there is no point in studying complex designations in too much detail. And given the entry of LEDs into the market, it is better to find something modern and constantly evolving for your home and garden. As for efficiency, the dispute will clearly not be resolved in favor of discharge lamps, although for some time they successfully deposited the filament.

DRV and DLR lamp - which is better to choose

DLR stands for "Arc Mercury Fluorescent Lamp". The active luminous element in it is an electric arc that occurs between 2 electrodes and operates in mercury vapor.

The DRV lamp is a mercury tungsten lamp that operates without a choke. It looks like a combination of a DRL burner and a tungsten filament, the latter performing the function of an induction ballast.


On the right is a DRL lamp, on the left is a DRL lamp, the power of both is the same

Despite the similarity of DRL and DVR, there is still a difference between them:

  • To ignite a DRL, a ballast is required; for a DRL it is not needed (this is a chokeless bulb);
  • The luminous flux of the DRL is 40-50% lower than that of the DRL, but it turns on immediately and does not warm up for several minutes;
  • The service life of DRL is longer than that of DVR, since the tungsten filament breaks down quite quickly;
  • Many users also note that DRV light bulbs are more energy-consuming.

Operating principle of the DRL lamp

Each burner is made of transparent, refractory material that is resistant to chemical influences. For this, ceramic materials or quartz glass are used. The inert gas pumped inside has a precise dosage. The final electrical arc is created by adding metallic mercury, ensuring the lamp glows normally.

A significant disadvantage of DRL and DRV lamps is the low efficiency of the light-emitting element. Compared to other types of lamps produced by the Philips and OSRAM brands, the difference in the luminous efficiency of DRV and DRL does not exceed 30 lm/W. The product has an increased service life and can withstand voltage surges in the electrical network.

ModelRated voltage, VPower, WLength, mmDiameter, mmBaseLuminous flux, lmDurability, h
DRL-12512512517777E27600012 000
DRL-25013025022790E4013 50015 000
DRL-400135400290121E4025 00018 000
DRL-700140700356151E4040 00020 000
DRL-10001451000412168E4060 00018 000

DRL lamps: design and principle of operation of a gas-discharge lamp

Economical DRL lamps, the characteristics of which differ slightly from the characteristics of the DRV e40 device, have a more simplified design. Accordingly, they are easier to dispose of. Device components:

Expert opinion

It-Technology, Electrical power and electronics specialist

Ask questions to the “Specialist for modernization of energy generation systems”

Drv lamp abbreviation decoding According to the principle of operation, it is similar to sodium and mercury light sources, but unlike them it has a tungsten spiral, which allows you to turn on the device without an external ballast that regulates the starting voltage. Ask, I'm in touch!

Advantages and disadvantages of an electromagnetic choke

Now let's talk about the advantages and disadvantages. The advantages of an electromagnetic choke include:

  1. Relatively low cost.
  2. Simplicity of design.
  3. Durability.

Unfortunately, this device has a few more disadvantages. This:

  1. Large weight and dimensions.
  2. Flickering of a lamp with double the mains frequency.
  3. Buzzing.
  4. Low efficiency due to high inductive reactance.
  5. At negative voltages, the lamp may not start.
  6. Long startup (from 1 to 3 seconds).
  7. During a difficult start-up, the lamp may “blink” for a long time, causing its coils to burn out.

Scope of application

DRV light bulbs are used to illuminate large spaces: streets, open spaces (for example, parking lots), industrial facilities (open and closed).

DRLs are used for lighting:

  1. Streets and roads;
  2. Squares, courtyards, squares;
  3. Warehouses, workshops and other large industrial premises;
  4. Car parks and gas stations.


Lamps are regularly used to illuminate large spaces

DRV is used in the following places:

  1. Boulevards, squares, parks and other city blocks;
  2. At construction sites;
  3. Warehouses and industrial facilities;
  4. DRV 25 is used in greenhouses because it produces a redder color.

Application area

This light source was good in its time, but now there are more effective modern solutions. Technically, DVRs can also be used for street lighting, but they are used very rarely in this capacity. But they are still found in park areas, parking lots, and construction sites. This is due to the initial short service life.

More often they can be found indoors. They mainly illuminate production areas of industrial facilities and warehouses.

Thanks to the emission spectrum, DRV-250 can be successfully used for supplementary lighting of plants in greenhouse conditions. This applies only to the DRV-250 model.

Considering the shortcomings of these illuminators and their imminent removal from production, this lighting technology is losing its relevance.

    Related Posts
  • Selecting a current-limiting resistor for an LED
  • Aquarium lamps and fixtures: types, requirements and characteristics
  • Types of lamps with g4 socket, comparison, popular manufacturers and models, selection of drivers for g4 12V lamps

Safety regulations

When using a lamp, you must follow some safety rules:

  • Before installing the light bulb, you need to carefully unpack it and make sure there are no mechanical damages;
  • It is prohibited to screw in or operate a faulty lamp; you also cannot use an open lamp in an open place where it is not protected from wind or precipitation;


The light bulb must be intact

  • After installation, it is necessary to carry out a test by turning on the lamp for 10-15 minutes. After that it can be used. It is important to remember that DRV lamps take several minutes to light up;

Important! If the network voltage is higher than 220 V, the lamps will fail faster and their service life will end earlier.

  • Any installation of the lamp must be carried out only with the electricity turned off;
  • If the light bulb becomes dirty, wipe it with a dry soft cloth. Solvents or aggressive cleaning agents must not be used;
  • The lamp can be placed in any position - both horizontally and vertically;
  • Light bulbs should be stored in packaging, not dropped or broken, they should not be given to children or allowed to play with;
  • It is necessary to dispose of lamps by handing them over to a collection point for mercury lamps.


Due to mercury vapor, disposal must be carried out at special points

If the light bulb does break, you must:

  1. Ventilate the room for at least 30 minutes, after leaving it;
  2. Wear disposable gloves and sweep all large parts into a bag using paper or cardboard;
  3. Use a wet sponge or tape to collect small pieces. Mercury must be collected moving from the edges to the center;
  4. At the very end, clean using chlorine.


It is necessary to clean up the mercury spill site with chlorine

DRV and DRL light bulbs are often used to illuminate streets, warehouses, workshops and construction sites. They are easy to install and use, easy to install and change, and provide good quality light. However, both lamps are classified as hazard class 1 due to their mercury content and should be used with caution.

LED E-40 to replace DRL-250

Without advertising to certain brands, we can note the most reputable domestic and foreign companies that produce high-quality LED lamps in the E-40 base, which can replace the DRL-250:

E40 BRIGHTLUX IP65 60W – from 7000 rubles, E40 SAMSUNG 60W (Corn) – from 3000 rubles, E40 SDL-KS-60 60W 220V SMD Corn ( Euroled ) – from 4300 rubles, E40 Philips Corn – from 3500 rubles, E40 60w Corn ( Corn) Goled – from 3600 rubles,

conclusions

You can also remember that gas-discharge lamps such as DRL-250 and DRL-400 use mercury. They are harmful in themselves, and a large number of them in production is undesirable. Another weighty argument against mercury lamps is that they will cease to be produced approximately in 2022, then their LED analogues will occupy the lion’s share of the market. Those who say that the luminous flux of mercury lamps is higher than that of LED lamps forget that LED lamps have a higher color temperature. This fact visually neutralizes these differences. Thus, we can conclude that a lower luminous flux cannot be considered a serious disadvantage.

DRL lamps detailed description


In fact, DRL lamps are deciphered quite simply:

  1. D - means that the lighting fixtures are arc.
  2. R – mercury. Therefore, it is not recommended to use such lamps during home use. After all, if they accidentally break, the harm to the health of all people may be too great.
  3. L – luminescent.

As you may have noticed, decoding these lamps is quite simple. Now let’s remember the main modifications of DRL. Now the most popular lamps are the following ratings:

The modifications are designated as follows: “DRL” + “number”, which is indicated above. Please note that the number is the lamp power in Watts, so when choosing, pay attention to the second indicator, it is the main one.

And this is what the design of DRL lamps looks like.

Rating
( 2 ratings, average 4.5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]